A sample of our work across Palm Beach County and the Treasure Coast.
Upgraded the main electrical service from 200 amps to 400 amps for a 15,000 sq ft multi-tenant office building on Clematis Street. The project included replacing the outdated Federal Pacific panel with a modern Square D panel, adding 42 new branch circuits, and installing surge protection for the building's server room. Work was completed over a weekend to minimize tenant disruption.
Installed dual Tesla Wall Connector units in a three-car garage at a PGA National estate. The project required running 120 feet of conduit from the main panel, adding a dedicated 60-amp sub-panel in the garage, and configuring load-sharing between the two chargers. Both units were connected to the homeowner's Tesla app for scheduled overnight charging during off-peak utility rates.
Completed a whole-house copper rewire of a 1,400 sq ft 1950s bungalow that still had original cloth-wrapped aluminum wiring. The scope included 200-amp panel upgrade, new AFCI and GFCI protected circuits throughout, dedicated circuits for kitchen appliances, and restoration of original period light fixtures with modern wiring. The home passed inspection on the first visit and the owner's insurance was reinstated.
Responded to an after-hours call when a 48-unit oceanfront condominium lost power to 16 units due to a corroded main bus connection in the building's distribution panel. Our team arrived within 45 minutes, isolated the failure, performed an emergency bus bar repair, and restored power to all affected units within three hours. A full panel replacement was scheduled and completed the following week.
Conducted a comprehensive electrical inspection and code compliance audit for a 6,000 sq ft law office occupying the second floor of a commercial building. Identified 14 code violations including missing GFCI protection in the break room, overloaded circuits serving the server closet, and improperly rated extension cords used as permanent wiring. All violations were remediated within two weeks and the space passed re-inspection.
Diagnosed and resolved persistent flickering lights affecting an entire wing of a 3,200 sq ft home in Jonathan's Landing. Thermal imaging revealed a failing 40-amp breaker with internal arcing that was intermittently dropping voltage to three branch circuits. Replaced the breaker, re-torqued all panel connections, and identified two additional outlets with deteriorated backstab connections that were replaced with commercial-grade receptacles.